Karl Fischer Buffers and Reagents
Buffers and reagents intended for use with Karl Fischer (KF) titration techniques. KF titration is a classic titration method that uses coulometric or volumetric titration to determine the moisture content of a sample.
Karl Fischer (KF) reagents are used in the analytical technique developed by chemist Karl Fischer to accurately measure the water content of gases, liquids, and solids.
Key applications include:
- Analyzing water content in raw materials and finished products
- Estimating moisture in food, pharmaceuticals, chemicals, and petroleum products
- Determining the water content of laboratory samples.
Karl Fischer reagents contain a variety of chemicals in proprietary formulations. Consult the SDS for individual products for appropriate handling instructions and precautions.
- (9)
- (1)
- (1)
- (2)
- (1)
- (4)
- (8)
- (1)
- (6)
- (1)
- (11)
- (1)
- (3)
- (4)
- (4)
- (1)
- (1)
Filtered Search Results
HYDRANAL™-Buffer Base, Honeywell Fluka™
Liquid buffer medium for Karl Fischer titration in alkaline samples (based on salicylic acid)
| CAS | 121-44-8 |
|---|---|
| MDL Number | MFCD00147178 |
| Health Hazard 2 | P210-P280-P304 + P340 + P312-P305 + P351 + P338 + P310-P370 + P378-P403 + P235 |
| Flash Point | 11°C (51.8°F) |
| UN Number | UN1993BE |
| Chemical Name or Material | HYDRANAL™-Buffer Base |
HYDRANAL™ - Coulomat E, Reagent for coulometric KF titration (ethanol-based), for cells with and without diaphragm, Honeywell Fluka™
Anolyte for coulometric Karl Fischer titration (ethanol-based), for cells with and without diaphragm
| CAS | 111-42-2 |
|---|---|
| Health Hazard 2 | P201-P210-P280-P308 + P313-P370 + P378-P403 + P235 |
HYDRANAL™ - Titrant 5 E, Reagent for volumetric two-component Karl Fischer titration (ethanol based), Honeywell™ Fluka™
Titrating agent for volumetric two-component Karl Fischer titration (ethanol-based)
| UN Number | UN1170 |
|---|
Karl Fischer Reagent Solution A, for pyridine-based volumetric KF titration (pyridine, sulfur dioxide, methanol), Honeywell™ Fluka™
for pyridine-based volumetric Karl Fischer titration (pyridine, sulfur dioxide, methanol)
| Health Hazard 2 | P210-P260-P280-P301 + P310 + P330-P303 + P361 + P353-P304 + P340 + P310-P305 + P351 + P338-P308 + P311-P403 + P233 |
|---|
| UN Number | UN1170 |
|---|
HYDRANAL™ - NEXTGEN Coulomat AG-FI, Honeywell Fluka™
Anolyte for coulometric Karl Fischer titrations, for cells with and without diaphragm
| Boiling Point | 64°C to 65°C (Methanol) |
|---|---|
| CAS | 67-56-1 |
| Color | Yellow |
| Solubility Information | Completely Miscible in Water |
| Packaging | Glass Bottle |
| Flash Point | 14°C |
| Physical Form | Liquid |
| CAS Min % | ≥60% |
| UN Number | UN1230 |
| Chemical Name or Material | HYDRANAL™ - NEXTGEN Coulomat AG-FI |
| Recommended Storage | Room Temperature |
| Density | 0.893 g/cm3 (at 20°C) |
| Melting Point | -98°C (Methanol) |
HYDRANAL™ - NEXTGEN Coulomat C-FA, Honeywell Fluka™
Catholyte for coulometric Karl Fischer titration of ketones and Li-ion battery electrolytes, Acetonitrile-based, free of alcohols (free of CMR substances).
| Color | Orange |
|---|---|
| Physical Form | Liquid |
| CAS Min % | ≥60.00 |
| UN Number | UN2924 |
| Chemical Name or Material | HYDRANAL™ - NEXTGEN Coulomat C-FA |
| Density | 0.906 g/cm3 |
| CAS | 75-05-8 |
| Solubility Information | Soluble in water |
| Packaging | Ampoule |
| Flash Point | 12°C to 13°C |
| pH | 5.5 |
| Recommended Storage | Room Temperature |
| Shelf Life | 720 days |
| CAS Max % | <70.00 |
HYDRANAL™ - NEXTGEN Solvent FI, Honeywell Fluka™
Medium for volumetric, two-component Karl Fischer titrations
| CAS | 147-85-3 |
|---|---|
| Solubility Information | Completely Miscible in Water |
| Packaging | Glass Bottle |
| Flash Point | 11°C |
| Physical Form | Liquid |
| pH | 5 to 6 |
| CAS Min % | ≥0.10% |
| UN Number | UN1230 |
| Chemical Name or Material | HYDRANAL™ - NEXTGEN Solvent FI |
| Recommended Storage | Room Temperature |
| Density | 0.9 g/cm3 (at 20°C) |
| CAS Max % | ≤5% |
HYDRANAL™-Solvent E, Honeywell Fluka™
Medium for volumetric two-component Karl Fischer titration (ethanol-based)
| CAS | 7446-09-5 |
|---|---|
| MDL Number | MFCD01867183 |
| Health Hazard 2 | P201-P210-P280-P308 + P313-P370 + P378-P403 + P235 |
| Flash Point | 12°C (53.6°F) |
| UN Number | UN1170 |
| Chemical Name or Material | HYDRANAL™-Solvent E |
| Density | 0.90g/mL |
HYDRANAL™-CompoSolver E, Honeywell Fluka™
Medium for volumetric one-component Karl Fischer titration (ethanol-based)
| CAS | 7446-09-5 |
|---|---|
| Health Hazard 2 | P201-P210-P280-P308 + P313-P370 + P378-P403 + P235 |
| Flash Point | 12°C (53.6°F) |
| UN Number | UN1170 |
| Chemical Name or Material | HYDRANAL™-CompoSolver E |
| Density | 0.80g/mL |
HYDRANAL™ - NEXTGEN Solvent E-FI, Honeywell Fluka™
Medium for volumetric, two-component Karl Fischer titrations
| CAS | 64-17-5 |
|---|---|
| Color | Colorless |
| Solubility Information | Completely Miscible in Water |
| Packaging | Glass Bottle |
| Physical Form | Liquid |
| pH | 5 to 6 |
| CAS Min % | ≥55% |
| UN Number | UN1170 |
| Chemical Name or Material | HYDRANAL™ - NEXTGEN Solvent E-FI |
| Density | 0.895 g/cm3 |
| CAS Max % | ≤80% |
| Melting Point | -115°C |
HYDRANAL™ - NEXTGEN Coulomat A-FA, Honeywell Fluka™
Anolyte for coulometric Karl Fischer titration of ketones and Li-ion battery electrolytes, preferred for cells with diaphragm, acetonitrile-based, free of alcohols (free of CMR substances)
| Color | Orange |
|---|---|
| Solubility Information | Soluble in water |
| Packaging | Glass Bottle |
| Flash Point | 12°C to 13°C |
| Physical Form | Liquid |
| pH | 5.5 |
| Chemical Name or Material | HYDRANAL™ - NEXTGEN Coulomat A-FA |