Karl Fischer Buffers and Reagents
Buffers and reagents intended for use with Karl Fischer (KF) titration techniques. KF titration is a classic titration method that uses coulometric or volumetric titration to determine the moisture content of a sample.
Karl Fischer (KF) reagents are used in the analytical technique developed by chemist Karl Fischer to accurately measure the water content of gases, liquids, and solids.
Key applications include:
- Analyzing water content in raw materials and finished products
- Estimating moisture in food, pharmaceuticals, chemicals, and petroleum products
- Determining the water content of laboratory samples.
Karl Fischer reagents contain a variety of chemicals in proprietary formulations. Consult the SDS for individual products for appropriate handling instructions and precautions.
- (4)
- (57)
- (1)
- (1)
- (1)
- (4)
- (3)
- (2)
- (3)
- (2)
- (3)
- (1)
- (27)
- (1)
- (2)
- (1)
- (4)
- (1)
- (13)
- (2)
- (1)
- (5)
- (41)
- (1)
- (1)
- (36)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (2)
- (22)
- (1)
- (2)
- (1)
- (53)
- (1)
- (1)
- (1)
- (12)
- (3)
- (1)
- (1)
- (24)
- (1)
- (3)
- (3)
- (1)
- (4)
- (2)
- (1)
- (1)
- (4)
- (8)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (3)
- (4)
- (5)
- (1)
- (1)
- (2)
Filtered Search Results
Karl Fischer Aqualine™ Electrolyte A, for Karl Fischer Titration By Coulometry, Fisher Chemical
Anolyte solution for general use in conventional cells with a diaphragm
HYDRANAL™-Buffer Base, Honeywell Fluka™
Liquid buffer medium for Karl Fischer titration in alkaline samples (based on salicylic acid)
| CAS | 121-44-8 |
|---|---|
| MDL Number | MFCD00147178 |
| Health Hazard 2 | P210-P280-P304 + P340 + P312-P305 + P351 + P338 + P310-P370 + P378-P403 + P235 |
| Flash Point | 11°C (51.8°F) |
| UN Number | UN1993BE |
| Chemical Name or Material | HYDRANAL™-Buffer Base |
HYDRANAL™ - NEXTGEN Coulomat AG-FI, Honeywell Fluka™
Anolyte for coulometric Karl Fischer titrations, for cells with and without diaphragm
| Boiling Point | 64°C to 65°C (Methanol) |
|---|---|
| CAS | 67-56-1 |
| Color | Yellow |
| Solubility Information | Completely Miscible in Water |
| Packaging | Glass Bottle |
| Flash Point | 14°C |
| Physical Form | Liquid |
| CAS Min % | ≥60% |
| UN Number | UN1230 |
| Chemical Name or Material | HYDRANAL™ - NEXTGEN Coulomat AG-FI |
| Recommended Storage | Room Temperature |
| Density | 0.893 g/cm3 (at 20°C) |
| Melting Point | -98°C (Methanol) |
HYDRANAL™ - NEXTGEN Coulomat C-FA, Honeywell Fluka™
Catholyte for coulometric Karl Fischer titration of ketones and Li-ion battery electrolytes, Acetonitrile-based, free of alcohols (free of CMR substances).
| Color | Orange |
|---|---|
| Physical Form | Liquid |
| CAS Min % | ≥60.00 |
| UN Number | UN2924 |
| Chemical Name or Material | HYDRANAL™ - NEXTGEN Coulomat C-FA |
| Density | 0.906 g/cm3 |
| CAS | 75-05-8 |
| Solubility Information | Soluble in water |
| Packaging | Ampoule |
| Flash Point | 12°C to 13°C |
| pH | 5.5 |
| Recommended Storage | Room Temperature |
| Shelf Life | 720 days |
| CAS Max % | <70.00 |
HYDRANAL™ - Titrant 5, Honeywell Fluka™
Titrating agent for volumetric, two-component Karl Fischer titrations (Methanol-based)
| Boiling Point | 65°C (at 1.013 hPa) |
|---|---|
| Color | Brown |
| Physical Form | Liquid |
| UN Number | UN1230 |
| Chemical Name or Material | HYDRANAL™ - Titrant 5 |
| Grade | Volumetric Two-Component KF Titration |
| Density | 0.850 g/cm3 (at 20°C) |
| CAS | 7553-56-2 |
| Solubility Information | Completely Miscible in Water |
| Packaging | Metrohm OMNIS Smart Reagent |
| Flash Point | 11°C |
| pH | Neutral |
| Synonym | Methyl Alcohol |
| Recommended Storage | Ambient |
| Melting Point | -98°C |
Karl Fischer Reagent Solution A, for pyridine-based volumetric KF titration (pyridine, sulfur dioxide, methanol), Honeywell™ Fluka™
for pyridine-based volumetric Karl Fischer titration (pyridine, sulfur dioxide, methanol)
| Health Hazard 2 | P210-P260-P280-P301 + P310 + P330-P303 + P361 + P353-P304 + P340 + P310-P305 + P351 + P338-P308 + P311-P403 + P233 |
|---|
HYDRANAL™ - NEXTGEN Coulomat A-FA, Honeywell Fluka™
Anolyte for coulometric Karl Fischer titration of ketones and Li-ion battery electrolytes, preferred for cells with diaphragm, acetonitrile-based, free of alcohols (free of CMR substances)
| Color | Orange |
|---|---|
| Solubility Information | Soluble in water |
| Packaging | Glass Bottle |
| Flash Point | 12°C to 13°C |
| Physical Form | Liquid |
| pH | 5.5 |
| Chemical Name or Material | HYDRANAL™ - NEXTGEN Coulomat A-FA |
HYDRANAL™-Solvent E, Honeywell Fluka™
Medium for volumetric two-component Karl Fischer titration (ethanol-based)
| CAS | 7446-09-5 |
|---|---|
| MDL Number | MFCD01867183 |
| Health Hazard 2 | P201-P210-P280-P308 + P313-P370 + P378-P403 + P235 |
| Flash Point | 12°C (53.6°F) |
| UN Number | UN1170 |
| Chemical Name or Material | HYDRANAL™-Solvent E |
| Density | 0.90g/mL |
| Boiling Point | 60°C |
|---|---|
| CAS Min % | ≥20.0000% |
| UN Number | UN1992 |
| Chemical Name or Material | HYDRANAL™ - Coulomat AK |
| Grade | Karl Fischer |
| Density | 1.200 g/cm3 |
| Name Note | Reagent for coulometric KF titration in ketones (anolyte solution), preferred for cells with diaphragm |
| CAS | 109-86-4 |
| Packaging | Glass Bottle |
| Flash Point | 32°C |
| DOT Information | Transport Hazard Class: 3; Packing Group:3: III; Proper Shipping Name: Flammable liquids, toxic, n.o.s. |
| Recommended Storage | Room Temp |
| Shelf Life | 1800 days from date of manufacture |
| CAS Max % | <5.0000% |
| MDL Number | MFCD00147197 |
|---|
HYDRA-POINT™ Coulometric Vessel Solution, CFC Free, BAKER ANALYZED™ Reagent, J.T. Baker™
High quality chemicals for laboratory and specialized industrial use
| Name Note | CFC Free |
|---|---|
| Packaging | Narrow Mouth Amber Glass Bottle |
| Flash Point | 55.60°C |
| Chemical Name or Material | HYDRA-POINT™ Coulometric Vessel Solution |
| Grade | BAKER ANALYZED™ Reagent |