missing translation for 'onlineSavingsMsg'
Learn More

Eppendorf™ Centrifuge 5425/5425 R
BIOPHARMAGREENER_CHOICE

Product Code. 17474152 Shop All Eppendorf Products
Change view
Click to view available options
Electrical Requirements:
230V/50–60Hz (EU)
230V/50–60Hz (GB)
Model:
Centrifuge 5425
Centrifuge 5425 (EU-IVD)
Centrifuge 5425 R
Centrifuge 5425 R (EU-IVD)
Refrigerated:
No
Yes
Rotor Included:
FA-24x2
No
Yes
Unit Size:
1 set
Each
22 product options available for selection
Product selection table with 22 available options. Use arrow keys to navigate and Enter or Space to select.
Product Code. Electrical Requirements Model Refrigerated Rotor Included unitSize
17474152 230V/50–60Hz (EU) Centrifuge 5425 (EU-IVD) No Yes 1 set
15831645 230V/50–60Hz (EU) Centrifuge 5425 (EU-IVD) No Yes Each
15841645 230V/50–60Hz (GB) Centrifuge 5425 (EU-IVD) No Yes Each
15851635 230V/50–60Hz (EU) Centrifuge 5425 (EU-IVD) No Yes Each
15861635 230V/50–60Hz (GB) Centrifuge 5425 (EU-IVD) No Yes Each
15871645 230V/50–60Hz (EU) Centrifuge 5425 (EU-IVD) No No Each
15891635 230V/50–60Hz (EU) Centrifuge 5425 (EU-IVD) No No Each
15811645 230V/50–60Hz (EU) Centrifuge 5425 No No Each
15851645 230V/50–60Hz (EU) Centrifuge 5425 No FA-24x2 Each
15861645 230V/50–60Hz (GB) Centrifuge 5425 No Yes Each
15871635 230V/50–60Hz (EU) Centrifuge 5425 No Yes Each
15881635 230V/50–60Hz (GB) Centrifuge 5425 No Yes Each
15891645 230V/50–60Hz (EU) Centrifuge 5425 No No Each
16855100 230V/50–60Hz (EU) Centrifuge 5425 R Yes Yes 1 set
16895100 230V/50–60Hz (EU) Centrifuge 5425 R Yes No Each
16835110 230V/50–60Hz (EU) Centrifuge 5425 R Yes Yes 1 set
16875110 230V/50–60Hz (EU) Centrifuge 5425 R Yes No Each
16835100 230V/50–60Hz (EU) Centrifuge 5425 R (EU-IVD) Yes Yes 1 set
16875100 230V/50–60Hz (EU) Centrifuge 5425 R (EU-IVD) Yes No Each
16815110 230V/50–60Hz (EU) Centrifuge 5425 R (EU-IVD) Yes Yes 1 set
16855110 230V/50–60Hz (EU) Centrifuge 5425 R (EU-IVD) Yes No Each
16672832 230V/50–60Hz (EU) Centrifuge 5425 No Yes Each
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 22 options available.
22 options
This item is not returnable. View return policy
Product Code. 17474152 Supplier Eppendorf™ Supplier No. 5405000158

Please to purchase this item. Need a web account? Register with us today!

This item is not returnable. View return policy

Eppendorf’s newest 24-place microcentrifuges, Centrifuge 5425 and 5425 R, feature ergonomic operation and a large selection of rotors with a maximum speed of up to 21,300 x g, making them perfectly suited for all modern molecular biological applications in Eppendorf and PCR tubes from 0.2 to 5 mL.

  • Aerosol-tight Eppendorf QuickLock™ lids for simple and safe handling
  • Outstanding software features (e.g. adjustable acceleration and braking ramps, 3 program buttons (only Centrifuge 5425), short function without continuous pressing of the key)
  • Extended rotor program (e.g. 5.0 mL rotor, swing-bucket rotor for PCR strips)
  • OptiBowl™ design for quiet operation, even without a rotor lid
  • Soft-touch one-finger lid closure for ergonomic operation
  • Max. rotor capacity: 10 × 5.0 mL vessels
  • Max. speed: 21,300 × g (15,060 rpm)
TRUSTED_SUSTAINABILITY

Spezifikation

Capacity 10 x 5.0 mL
Max. Speed 15,060 rpm
Max. RCF 21,300 x g
Display Large, Brightly Lit LCD
Height (English) Exterior 9.5 in.
Height (Metric) Exterior 24 cm
Noise Level Average of 45 dB(A) in the first 12 minutes and < 51 dB(A) thereafter with Rotor FA-24x2.
Timer 10 sec. to 9 hr. 59 min., with continuous run function
Width (English) Exterior 9.5 in.
Width (Metric) Exterior 24 cm
Certifications/Compliance UL (120 V), CAN/CSA (120 V), CE, RoHS, IVD for certain catalog numbers
Includes Rotor FA-18x2-Kit
Safety Features Lid Lock, steel armoured safety chamber, view port for speed validation, lid emergency release, automatic rotor recognition, certified aerosol-tight rotor lids, automatic imbalance recognition
Electrical Requirements 230V/50–60Hz (EU)
Controller Type Rotary Knob
Model Centrifuge 5425 (EU-IVD)
Wattage 280 W
Rotor Included Yes
Refrigerated No
Standards EN ISO 14971, EN 61010-2-101, EN 61326-2-6, EN 62366, EN ISO 18113-1, EN ISO 18113-3, EN ISO 15223-1, EN 61010-1, EN 61010-2-020, IEC 61010-1, IEC 61010-2-020, EN 55011, EN 61326-1, EN 50581, IEC 61010-2-101, UL 61010-1, UL 61010-2-020, CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-020, 47 CFR FCC Part 15 (refer to manual for more details)
Product Line Centrifuge 5425 (EU-IVD)
Voltage 230 V
Rotor FA-18x2-Kit
Mehr anzeigen Weniger anzeigen

The Centrifuge 5425 is designed for separating liquid substance mixtures with different densities, in particular, for processing and analyzing samples from the human body in in-vitro diagnostic applications to ensure that the in-vitro diagnostic device can be used according to its intended purpose. This centrifuge including components is an in-vitro diagnostic device according to Directive 98/79/EC of the European Parliament and the Council dated October 27, 1998. Eppendorf centrifuges are exclusively intended for indoor use by trained specialists.

Name des Produkts
Wählen Sie ein Thema

Indem Sie auf Absenden klicken, erklären Sie sich damit einverstanden, dass Fisher Scientific sich mit Ihnen in Verbindung setzen kann, um Ihr Feedback in diesem Formular zu bearbeiten. Wir werden Ihre Informationen nicht für andere Zwecke weitergeben. Alle bereitgestellten Kontaktinformationen werden in Übereinstimmung mit unserer Datenschutzrichtlinie aufbewahrt. Datenschutzrichtlinie.