missing translation for 'onlineSavingsMsg'
Learn More

Cytiva HiScreen™ Capto™ Phenyl (High Sub) Prepacked HIC Column

Hydrophobic interaction chromatography (HIC) media used in the capture and intermediate stages of protein purification, used for method optimization and parameter screening

Brand:  Cytiva 28-9924-72

Additional Details : Weight : 0.08300kg


Product Code. 11648943

  • € 171.00 / Each
Estimated Shipment: 07-06-2024
to see stock.
Add to basket

Description

Description

  • Highly cross-linked agarose matrix with average bead size of 75μm
  • Has good flow properties and high loading capacities
  • Bed height of 10cm designed to allow method optimization and parameter screening
  • Connect easily in series to achieve 20cm bed height
  • Small bed volume gives fast results and minimal sample/buffer consumption
  • Capto Phenyl (high sub) media is used for initial and intermediate step purifications requiring a chromatography medium with medium to high hydrophobicity
  • Combines high capacity with high flow velocity and low backpressure to reduce process cycle times and increase productivity
  • Reproducible results, scalable to BioProcess columns packed with the same chromatography media using the same linear fluid velocity

  • Bed volume: 4.7mL
  • Bed dimension: 7.7 × 100mm
  • Flow rate: 1.2 to 2.7mL/min.
  • Flow velocity: <600cm/hr.
Media
  • Average particle size: 75μm
  • Degree of substitution: 27μmol/mL gel
  • pH stability cleaning: 2 to 14
  • Pressure/Flow specification: 300kPa at 600cm/hr., 1m diameter column, 20cm bed height
  • Medium: BioProcess
  • pH stability working range: 3 to 13
  • Ligand: phenyl
  • Binding capacity/mL chromatography medium: 27mg BSA /mL (at QB10%)
Column
  • Bed support: filter
  • Material (column hardware and column tube): polypropylene
  • Column I.D.: 7.7mm

Specifications

Specifications

Aqueous Buffer
4.7mL
7.7mm
3.93 in.
<600cm/hr.
Phenyl (∼27μM/mL drained medium)
3 to 13
Highly Cross-linked Agarose
HIC Column
HiScreen Capto Phenyl (high sub) column
0.3 in.
1 x 4.7mL
100mm
Polypropylene
43.5psi
75μm
4° to 30°C
Optimization and parameter screening
Product Suggestions

Product Suggestions

Videos
Safety and Handling

Safety and Handling

Product Identifier
  • HiScreen Capto Phenyl (high sub), 1 x 4.7 ml

Signal Word
  • Warning

Hazard Category
  • Flammable liquid Category 3

Hazard Statement
  • H226-Flammable liquid and vapour.

Precautionary Statement
  • P280-Wear protective gloves/protective clothing/eye protection/face protection.
  • P210-Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P241-Use explosion-proof electrical/ventilating/lighting/and all material-handling/ equipment.
  • P303+P361+P353-IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/ shower.
  • P235-Keep cool.
  • P501b-Dispose of contents/container in accordance with local/regional/national/international regulations.

Supplemental information
  • MIXTURE LIST-Contains : ethanol

SDS
Documents

Documents

Certificates
Special Offers

Special Offers