Thermo Scientific™ Holmium Oxide Solution Verification Standard

Código de producto. 11823654 Tienda Thermo Scientific Productos
Cambiar vista
Click to view available options
Type:
Holmium Oxide in Perchloric Acid Solution
Tamaño de la unidad:
Each
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Código de producto. Type unitSize
11823654 Holmium Oxide in Perchloric Acid Solution Each
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Este artículo no se puede devolver. Vea la política de devoluciones
This standard is qualified for use on instruments having a spectral bandwidth of <3nm.
Código de producto. 11823654 Proveedor Thermo Scientific™ N.º de proveedor 222226400
  • ONLINE EXCLUSIVE PRICE
    € 1300.00
    € 1235.67 / Pack of 1
    Save € 64.33
    4% Off
 Restricted Item
Estimated Shipment: 14-08-2026
Añadir a la cesta
Añadir a la cesta
Este artículo no se puede devolver. Vea la política de devoluciones
This standard is qualified for use on instruments having a spectral bandwidth of <3nm.

Thermo Scientific™ NIST™-traceable Holmium Oxide Solution Standard verifies wavelength accuracy of UV-Visible spectrophotometers.

Thermo Scientific NIST™-traceable Holmium Oxide Solution Standard verifies wavelength accuracy of UV-Visible spectrophotometers.

Holmium Oxide in Perchloric Acid Solution is a preferred standard for verifying the wavelength accuracy of a spectrophotometer according to international pharmacopoeia guidelines.
  • Permanently sealed in a quartz cuvette allowing it to be used into the deep UV range
  • Exhibits sharp, stable peaks within the range of 219 to 650nm—can be easily correlated to wavelengths of the peak maxima
  • Readings observed for each peak are verified against expected values on the certificate supplied with the standard
  • Readings not within the expected range may be indicative of an instrument performance error

This standard is qualified for use on instruments having a spectral bandwidth of <3nm.
TRUSTED_SUSTAINABILITY

Especificaciones

Calibration NIST/NPL Traceable
Description Wavelength Standard; Verification Standard
Type Holmium Oxide in Perchloric Acid Solution
Título del producto
Seleccione un problema

Al hacer clic en Enviar, acepta que Fisher Scientific se ponga en contacto con usted en relación con los comentarios que ha proporcionado en este formulario. No compartiremos su información para ningún otro fin. Toda la información de contacto proporcionada se mantendrá de acuerdo con nuestra Política de Privacidad. Política de privacidad.