missing translation for 'onlineSavingsMsg'
Läs mer

Thermo Scientific™ TraceGOLD™ TG-PAH GC Columns

Produktkod. 15978200 Handla allt Thermo Scientific Produkter
Change view
Klicka för att se tillgängliga alternativ
Length (Metric):
30 m
40 m
60 m
Diameter (Metric):
0.18 mm
0.25 mm
Film Thickness:
0.07 μm
0.1 μm
Förpackningsstorlek:
Each
3 product options available for selection
Product selection table with 3 available options. Use arrow keys to navigate and Enter or Space to select.
Produktkod. Length (Metric) Diameter (Metric) Film Thickness unitSize
15978200 40 m 0.18 mm 0.07 μm Each
15968200 30 m 0.25 mm 0.1 μm Each
15958200 60 m 0.25 mm 0.1 μm Each
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 3 options available.
3 options
Denna artikel kan inte returneras. Se returpolicy
Produktkod. 15978200 Leverantör Thermo Scientific™ Leverantörsnummer 260553570
Bara null kvar
Lägg i varukorgen
Lägg i varukorgen
Denna artikel kan inte returneras. Se returpolicy

Use these thermally stable TraceGOLD TG-PAH GC columns for fast analysis of regulated polycyclic aromatic hydrocarbons (PAHs) in complex food and environmental samples.

Perform rapid analysis of regulated PAHs such as persistent organic pollutants (POPs) in complex food and environmental samples using Thermo Scientific™ TraceGOLD™ TG-PAH GC columns. High selectivity and maximum resolution of this capillary silica based column, combined with its unique bonded chemistry, ensure accurate separation of isobaric compounds even at very low concentration levels. The TraceGOLD TG-PAH GC column is regarded as highly robust due to the exceptionally high thermal stability and long life time. Sensitivity is of paramount importance in meeting regulatory standards in the challenging trace analysis.

Designed for high resolution analysis of polycyclic aromatic hydrocarbons (PAHs) in complex food and environmental samples.

Key benefits
  • Fast analysis of regulated PAHs
  • Maximize resolution for critical isobaric PAHs
  • Max. temperature of 360°C
  • Low column bleed
TRUSTED_SUSTAINABILITY

Specifikationer

Diameter (Metric) 0.18 mm
Product Line TraceGOLD
Stationary Phase TraceGOLD™ PAH
For Use With (Application) Gas Chromatography (GC)
Film Thickness 0.07 μm
Length (Metric) 40 m
Produkttitel
Välj ett problem

Genom att klicka på Skicka bekräftar du att du kan bli kontaktad av Fisher Scientific angående feedbacken du har lämnat i detta formulär. Vi kommer inte att dela din information för andra ändamål. All kontaktinformation som tillhandahålls ska också underhållas i enlighet med vår Sekretesspolicy.