Applied Biosystems™ PowerUp™ SYBR™ Green Master Mix for qPCR
Pre-formulated, optimized, universal 2X master mix for real-time PCR workflows.
| Shipping Condition | Wet Ice |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Dual-Lock Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System, Roche LightCycler PRO System, Bio-Rad CFX Opus 96 Real-Time PCR System |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | Medium |
| Target Specificity | cDNA or gDNA only |
| Product Line | PowerUP, SYBR |
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Master Mix for qPCR
TaqMan Fast Virus 1-Step Master Mix is designed for fast, highly sensitive real-time RT-PCR, even in the presence of challenging PCR inhibitors.
| Shipping Condition | Dry Ice |
|---|---|
| Reverse Transcriptase | M-MLV |
| Form | Liquid |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 3-plex |
| Detection Method | Primer-probe |
| Thermostability | Not Applicable |
| Polymerase | AmpliTaq Fast DNA Polymerase |
| Format | Tube |
| Product Type | 1-Step Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System |
| Sample Type | Total RNA, Viral DNA, Viral RNA, mRNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
| Product Line | TaqMan |
Applied Biosystems™ TaqPath™ ProAmp™ Master Mix
TaqPath ProAmp Master Mix is for high-throughput genotyping and copy number variation protocols requiring uncompromising reliability and accuracy, even in the presence of inhibitors commonly found in clinical samples.
| Shipping Condition | Wet Ice |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
| Multiplex Capability | 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 7 Flex, ViiA 7 System, ViiA 7 Dx, QuantStudio Dx, StepOnePlus System, StepOne System |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | Very High |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqPath |
Applied Biosystems™ AgPath-ID™ One-Step RT-PCR Reagents
AgPath-ID™ One-Step RT-PCR Reagents are designed for sensitive, robust amplification of RNA targets using a rapid single-tube TaqMan™ real-time reverse transcription PCR (RT-PCR) strategy.
| Shipping Condition | Dry Ice |
|---|---|
| GC-Rich PCR Performance | High |
| Fidelity (vs. Taq) | 25 X |
| Description | Works on all AB platforms, but is optimized for the 7500. |
| Reverse Transcriptase | ArrayScript™ |
| Concentration | 25X |
| PCR Method | 1-step RT-qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Format | Tube |
| Product Type | One-Step RT-PCR Reagent |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex, QuantStudio™ Absolute Q Digital PCR System |
| Sample Type | RNA |
| Reaction Speed | Standard |
| Product Line | AgPath-ID, Ambion |
Applied Biosystems™ TaqPath™ 1-Step Multiplex Master Mix
TaqPath 1-Step Multiplex Master Mix is a fast, single-tube, 4X RT-qPCR mix that provides for sensitive, reproducible detection of up to four different RNA/DNA targets in a single multiplex reaction.
| Shipping Condition | Dry Ice |
|---|---|
| Concentration | 4X |
| For Use With (Application) | Gene Expression,Microbial Detection |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | Not Applicable |
| Polymerase | Fast DNA Polymerase |
| Sensitivity | Down to 10 copies |
| Format | Tube |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | Mustang Purple |
| For Use With (Equipment) | QuantStudio 6 Pro Real-Time PCR System or QuantStudio 7 Pro, QuantStudio 3 or 5, QuantStudio 6/QuantStudio 7 Flex, QuantStudio 12K Flex, QuantStudio Dx, ViiA 7, 7500 , 7500 Fast, 7500 Fast Dx |
| Sample Type | DNA, RNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | RNA only, Both RNA and DNA |
| Product Line | TaqPath |
Applied Biosystems™ TaqMan™ GTXpress™ Master Mix
Combines AmpliTaq™ Fast DNA Polymerase, UP, dNTPs, Tracking Dye, and ROX™ dye in a convenient single vial format.
| GC-Rich PCR Performance | High |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
Invitrogen™ EXPRESS One-Step Superscript™ qRT-PCR Kit, universal
Kit incorporates proven Invitrogen™ enzymes specifically tailored to deliver superior results on high-throughput, fast-cycling instruments for probe-based qPCR experiments.
| Polymerase | Taq DNA Polymerase |
|---|---|
| Format | Tube |
| Product Type | qRT-PCR Kit |
| For Use With (Equipment) | 7500 Fast System, 7500 System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, BioRad CFX96™, StepOnePlus™, Fast Mode, StepOnePlus™, Standard Mode, Stratagene Mx3000P, Stratagene Mx3005P, Stratagene Mx4000, BioRad MyiQ, Corbett RotorGene, Cepheid SmartCycler, MJ Opticon, MJ Chromo4, BioRad iCycler iQ |
| Sample Type | RNA |
| Reaction Speed | Fast or Standard |
| PCR Method | 1-step RT-qPCR |
| Product Line | SuperScript |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Multiplex Master Mix for qPCR (No ROX)
TaqMan Fast Virus 1-Step Multiplex Master Mix (No ROX) is designed to enable dye flexibility for multiplexing up to four different RNA/DNA targets for high-throughput RT-qPCR.
| Shipping Condition | Dry Ice |
|---|---|
| Concentration | 4X |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Thermostability | Not Applicable |
| Passive Reference Dye | None |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Flex, QuantStudio 7 Pro, StepOne, StepOnePlus, ViiA 7 System, Roche LightCycler PRO System, Bio-Rad CFX Opus 96 Real-Time PCR System |
| Sample Type | RNA, DNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
Applied Biosystems™ TaqMan™ Gene Expression Master Mix
Precise and reliable real-time qPCR quantification over 9 logs of linear dynamic range with Applied Biosystems™ TaqMan™ Gene Expression Master Mix.
| Polymerase | AmpliTaq Gold DNA Polymerase |
|---|---|
| Purity or Quality Grade | UP (Ultra Pure) |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7900HT System, Applied Biosystems StepOnePlus™ Fast Real-Time PCR SystemStepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | TaqMan |
| Detection Method | Primer-probe |
Applied Biosystems™ MycoSEQ™ Mycoplasma Detection Kits
The MycoSEQ Mycoplasma Detection Kit is a real-time mycoplasma PCR assay designed and validated to meet the requirements of European Pharmacopeia Chapter 2.6.7 for use as a nucleic acid amplification technique (NAT).
| Description | Detection for BioProduction process media, cells, raw materials |
|---|---|
| Label or Dye | SYBR Green |
| Quantity | 100 Reactions |
| For Use With (Application) | Mycoplasma Detection |
| Product Line | MycoSEQ |
Applied Biosystems™ TaqMan™ Universal Master Mix II, no UNG
TaqMan Universal Master Mix II is a convenient mix of components (except primers, probes, template, and water) necessary to perform a real-time polymerase chain reaction (PCR).
| GC-Rich PCR Performance | High |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. Guaranteed minimum shelf life is 60 days (exact expiry date printed on product and CofA). |
| Fidelity (vs. Taq) | 2 X |
| Purity or Quality Grade | UP (Ultra Pure) |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq Gold DNA Polymerase |
| Product Type | Universal Master Mix II |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7300 System, 7500 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, ViiA™ 7 System |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| Product Line | TaqMan |
Applied Biosystems™ TaqPath™ 1-Step Multiplex Master Mix (No ROX)
TaqPath 1-Step Multiplex Master Mix (No ROX) is a fast, single-tube, 4X RT-qPCR mix that provides for sensitive, reproducible detection of up to four different RNA/DNA targets in a single multiplex reaction.
| Shipping Condition | Dry Ice |
|---|---|
| For Use With (Application) | Microbial Detection,DNA Quantification,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | Not Applicable |
| Sensitivity | Down to 10 copies |
| Format | Tube |
| Passive Reference Dye | None |
| For Use With (Equipment) | QuantStudio 6 Pro or QuantStudio 7 Pro, QuantStudio 3 or 5, QuantStudio 6/QuantStudio 7 Flex, QuantStudio 12K Flex, QuantStudio Dx, ViiA 7, 7500, 7500 Fast, 7500 Fast Dx, or use a compatible real-time PCR instrument from another supplier |
| Sample Type | DNA, RNA |
| Reaction Speed | Fast or Standard |
| Inhibitor Tolerance (Simple) | High |
| Target Specificity | RNA only, Both RNA and DNA |
| Product Line | TaqPath |
Applied Biosystems™ Eukaryotic 18S rRNA Endogenous Control (FAM™/MGB probe, non-primer limited)
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Eukaryotic 18S rRNA Endogenous Control (FAM™/MGB probe, non-primer limited)
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | Control Primer-Probe Set(s) |
| Gene Symbol | 18S |
| Amplicon Size | 187 |
| Concentration | 20X |
| For Use With (Application) | Gene Expression |
| PCR Method | 2-step RT-qPCR |
| Detection Method | Primer-probe |
| Accession Number | X03205.1 |
| Target | 18S rRNA |
| Format | Tube |
| Label or Dye | FAM |
| Species | Eukaryotic, Rat, Mouse, Human |
| Product Line | FAM, TaqMan |
Applied Biosystems™ ViralSEQ™ Mouse Minute Virus (MMV) Detection System
The Applied Biosystems ViralSEQ Mouse Minute Virus (MMV) Detection Assay is part of an integrated DNA purification and real-time PCR-based system for rapid, sensitive detection of MMV from a wide range of sample types.
Applied Biosystems™ Absolute Q™ 1-step RT-dPCR Master Mix (4X)
Applied Biosystems Absolute Q 1-step RT-dPCR Master Mix (4X) is optimized for use with the QuantStudio Absolute Q Digital PCR System in a simple workflow with minimal processing steps.