Filtered Search Results
TaqMan™ Control Genomic DNA (human)
Conveniently packaged in a PCR-ready concentration for use as a control template in PCR reactions
Applied Biosystems™ PowerTrack™ SYBR Green Master Mix for qPCR
PowerTrack SYBR Green Master Mix is a pre-formulated, optimized, universal 2X master mix for real-time PCR workflows with built-in visual dye–based indicators for accurate reaction set up.
| Shipping Condition | Dry Ice |
|---|---|
| Content And Storage | • PowerTrack SYBR Green Master Mix • 40X Yellow Sample Buffer Store at -20±5°C in the dark. |
| InhibitorToleranceSimple | High |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Microbial Detection |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 8 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT Fast System, 7900HT System, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Flex, QuantStudio 7 Pro, QuantStudio 12K Flex, Bio-Rad CFX Connect, Bio-Rad CFX384 Touch, Bio-Rad CFX96 Touch, BioRad CFX96, BioRad iCycler iQ, BioRad iQ5, BioRad MyiQ, ViiA 7 System, StepOne System, MJ Chromo4, MJ Opticon, StepOnePlus System, Roche LightCycler 480, Stratagene Mx3000P, Stratagene Mx3005P, Stratagene Mx4000 |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | Applied Biosystems |
Applied Biosystems™ TaqMan™ Universal PCR Master Mix
TaqMan Universal PCR Master Mix is the ideal reagent solution when you need a master mix for multiple 5' nuclease DNA applications.
| Polymerase | AmpliTaq Gold DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Product Type | Universal PCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7000 System, 7300 System, 7500 System, 7700 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, GeneAmp 9600, StepOne™, Standard Mode, StepOnePlus™, Standard Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Product Line | TaqMan |
| Detection Method | Primer-probe |
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Multiplex Master Mix for qPCR (No ROX)
TaqMan Fast Virus 1-Step Multiplex Master Mix (No ROX) is designed to enable dye flexibility for multiplexing up to four different RNA/DNA targets for high-throughput RT-qPCR.
| Shipping Condition | Dry Ice |
|---|---|
| InhibitorToleranceSimple | High |
| Concentration | 4X |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantitation,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Thermostability | Not Applicable |
| Passive Reference Dye | None |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio™ 12k Flex, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 6 Pro, QuantStudio™ 7 Flex, QuantStudio™ 7 Pro, StepOne™, StepOnePlus™, ViiA™ 7 System |
| Sample Type | RNA, DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
Applied Biosystems™ Protein Thermal Shift™ Starter Kit
This solution significantly reduces the time and cost associated with screening samples relative to currently available methods.
Thermo Scientific™ Maxima Reverse Transcriptase (200 U/μL)
Thermo Scientific Maxima Reverse Transcriptase (RT) was developed through in vitro evolution of M-MuLV RT. The enzyme possesses an RNA-dependent and DNA-dependent polymerase activity as well as RNase H activity.
| Concentration | 200 U/μL |
|---|
Applied Biosystems™ TaqMan™ Fast Virus 1-Step Master Mix for qPCR
TaqMan Fast Virus 1-Step Master Mix is designed for fast, highly sensitive real-time RT-PCR, even in the presence of challenging PCR inhibitors.
| Shipping Condition | Dry Ice |
|---|---|
| Reverse Transcriptase | M-MLV |
| Form | Liquid |
| InhibitorToleranceSimple | High |
| For Use With (Application) | Microbial Detection,Gene Expression,DNA Quantitation,Presence/Absence |
| PCR Method | 1-step RT-qPCR |
| Multiplex Capability | Up to 3-plex |
| Detection Method | Primer-probe |
| Thermostability | Not Applicable |
| Polymerase | AmpliTaq Fast DNA Polymerase |
| Format | Tube |
| Product Type | 1-Step Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System |
| Sample Type | Total RNA, Viral DNA, Viral RNA, mRNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | RNA only, Both RNA and DNA |
| Hot Start | Built-In Hot Start |
| Product Line | TaqMan |
Thermo Scientific™ Maxima SYBR Green qPCR Master Mix (2X), with separate ROX vial
Ready-to-use solution optimized for qPCR and 2-step RT-qPCR.
| Polymerase | Taq DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| For Use With (Equipment) | BioRad CFX96™, MJ Chromo4, MJ Opticon, Eppendorf MasterCycler RealPlex, Bio-Rad CFX384 Touch™, Roche LightCycler 480, Cepheid SmartCycler, Corbett RotorGene |
| Sample Type | DNA, dsDNA |
| Reaction Speed | Standard |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | Maxima |
| Detection Method | SYBR |
Applied Biosystems™ TaqMan™ GTXpress™ Master Mix
Combines AmpliTaq™ Fast DNA Polymerase, UP, dNTPs, Tracking Dye, and ROX™ dye in a convenient single vial format.
| GC-Rich PCR Performance | High |
|---|---|
| Concentration | 2X |
| For Use With (Application) | Genotyping |
| PCR Method | qPCR |
Thermo Scientific™ Maxima SYBR Green/ROX qPCR Master Mix (2X)
Ready-to-use solution optimized for qPCR and 2-step RT-qPCR.
| Polymerase | Taq DNA Polymerase |
|---|---|
| GC-Rich PCR Performance | High |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| For Use With (Equipment) | 7000 System, 7300 System, 7700 System, 7900HT System, StepOnePlus™ System, StepOne™ System |
| Sample Type | DNA, dsDNA |
| Reaction Speed | Standard |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Product Line | Maxima |
| Detection Method | SYBR |
Applied Biosystems™ TaqMan™ Fast Universal PCR Master Mix (2X), no AmpErase™ UNG
TaqMan™ Fast Universal PCR Master Mix contains all of the components, excluding the template and primers, for superior real-time qPCR.
| GC-Rich PCR Performance | High |
|---|---|
| Fidelity (vs. Taq) | 2 X |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Genotyping,miRNA analysis |
| PCR Method | qPCR |
| Detection Method | Primer-probe |
| Polymerase | AmpliTaq DNA Polymerase |
| Format | Tube |
| Product Type | Fast Universal PCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7900HT Fast System, StepOne™, Fast Mode, StepOnePlus™, Fast Mode |
| Sample Type | DNA (Genomic), cDNA |
| Reaction Speed | Fast |
| Product Line | AmpErase, TaqMan |
Applied Biosystems™ PowerUp™ SYBR™ Green Master Mix for qPCR
Pre-formulated, optimized, universal 2X master mix for real-time PCR workflows.
| Shipping Condition | Wet Ice |
|---|---|
| InhibitorToleranceSimple | Medium |
| Concentration | 2X |
| For Use With (Application) | Gene Expression |
| PCR Method | qPCR |
| Multiplex Capability | Single-plex |
| Detection Method | SYBR |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Dual-Lock Taq DNA Polymerase |
| Format | Tube |
| Product Type | Real Time PCR SYBR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | 7500 Fast System, 7500 System, 7900HT System, QuantStudio 12k Flex, QuantStudio 3, QuantStudio 5, QuantStudio 6 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio 7 Flex, StepOne, StepOnePlus, ViiA 7 System |
| Sample Type | DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | PowerUP, SYBR |
Applied Biosystems™ TaqPath™ qPCR Master Mix, CG
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
TaqPath qPCR Master Mix, CG, is a 2X formulation designed for gene expression and miRNA analysis. It contains thermostable Fast DNA polymerase, uracil-N-glycosylase (UNG), dNTPs with dUTP, ROX dye (passive reference), and optimized buffer components for maximum robustness and reproducibility.
| Content And Storage | Store at 2°C to 8°C in the dark. |
|---|---|
| Form | Liquid |
| InhibitorToleranceSimple | High |
| Concentration | 2X |
| For Use With (Application) | Gene Expression,Microbial Detection,DNA Quantitation,Presence/Absence,miRNA analysis |
| PCR Method | qPCR |
| Multiplex Capability | Duplex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 48 hr., Assembled Reaction |
| Polymerase | Fast DNA Polymerase |
| Sensitivity | Down to 10 copies |
| Format | Bottle |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | ROX (Pre-mixed) |
| For Use With (Equipment) | QuantStudio Dx, 7500 Fast Dx |
| Sample Type | cDNA, DNA |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Hot Start | Built-In Hot Start |
| Product Line | TaqPath |
Applied Biosystems™ TaqPath™ ProAmp™ Multiplex Master Mix
TaqPath ProAmp Multiplex Master Mix is for higher multiplexing (up to four targets) in high-throughput genotyping and copy number variation protocols requiring uncompromising reliability and accuracy, even in the presence of inhibitors commonly found in clinical samples.
| Shipping Condition | Wet Ice |
|---|---|
| Content And Storage | Store at 2°C to 8°C in the dark. |
| InhibitorToleranceSimple | Very High |
| For Use With (Application) | Genotyping,Pharmacogenomics |
| PCR Method | qPCR |
| Multiplex Capability | Up to 4-plex |
| Detection Method | Primer-probe |
| Includes | dUTP, UNG/UDG |
| Thermostability | 72 hr., Assembled Reaction |
| Polymerase | Taq DNA Polymerase |
| Product Type | qPCR Master Mix |
| Passive Reference Dye | Mustang Purple |
| For Use With (Equipment) | QuantStudio 3 or 5, QuantStudio 6/QuantStudio 7 Flex, QuantStudio 12K Flex, QuantStudio Dx, ViiA 7 Real-Time PCR System ViiA 7 Dx, 7500 Fast, StepOne or StepOnePlus |
| Reaction Speed | Fast or Standard |
| Target Specificity | cDNA or gDNA only |
| Product Line | TaqPath |
Invitrogen™ SuperScript™ III Platinum™ One-Step qRT-PCR Kit w/ROX
One-Step qRT-PCR Kits with ROX combine the most powerful reverse transcriptase and DNA polymerase technologies to deliver precise and accurate analysis of gene expression.
| Shipping Condition | Dry Ice |
|---|---|
| Polymerase | Platinum Taq DNA Polymerase |
| For Use With (Equipment) | 7000 System, 7300 System, 7700 System, 7900HT System |
| Sample Type | RNA |
| Reaction Speed | Standard |
| For Use With (Application) | Gene Expression,Pathogen Detection,Virus Detection |
| PCR Method | 1-step RT-qPCR |
| Product Line | Platinum, SuperScript |
| Detection Method | Primer-probe |